MicroFAST® H
Septic Systems
|
|
There
is a growing worldwide concern over fresh water sources and ocean water
quality. The world's population is predicted to double by 2027
and millions more people will be without access
to clean water. Scientists from around the world are urging an immediate
adoption of clean waste processing technologies and the development of
infrastructures to protect water resources and delicately balanced
ecosystems. Ampac USA offers simple and affordable solutions to reduce
the ecological impact caused by the release of
untreated wastewater into our rivers, lakes and oceans. |
|
 |
|
AMPAC USA
FAST® Septic Systems: have been tested and approved by the Canadian
Standards Association (CSA), Canadian Great Lakes (CGL), the US
Environmental Protection Agency (EPA), the US Coast Guard, the US
Electrical Systems, the Underwriters Laboratories (UL), European Union
(CE), European Electrical Systems (including Tropical
Certification), National Sanitation Foundation, the U.K. Department Of
Trade, the International Maritime Organization (IMO), the Australian
Department Of Transportation, Royal Australian Navy, SASSO (Saudi
Arabia) |
|
 |
|
Dependable, Affordable MicroFAST®
MicroFAST® contain
no submersible pumps, sewage filters or moving parts to repair or
replace. All internal parts
are made
from durable, long lasting plastic, not subject to deterioration. All
tanks and bio-filters come with full ten year
warrantees. A two year complete inspection of each MicroFAST® System is included
free. |
|
 |
|
MicroFAST® comes in
seven sizes and capacities to provide the most cost efficient sewage
treatment for each individual application. The size of the home
and number of bedrooms determines the recommended model size.
The larger MicroFAST® model
sizes are recommended for clusters of residences, trailer parks and
subdivisions. The smallest MicroFAST® models are typically recommended
for the average size home or vacation property.
|
|
MicroFAST®
The system's only
moving part, the quiet aerating blower is
located above ground, in an unobtrusive pump housing
that can be placed up to 100 feet away. It needs no oil or
lubrication and the reusable air intake filter is easily
cleaned off twice a year
To activate the continuous circulation of wastewater through the
flowpath, the above ground air lift [3] introduces
air into the MicroFAST® System. |
|
 |
|

|
|
[1]
Sewage wastewater
from household drains flow into MicroFAST®
[2]
Natural separation and settling occur
as effluent enters the bio-reactor.
[3]
Remote air Blower
deliver large volume of air into the heart of the system, creating water
movement
[4] In
the bio-reactor, the MicroFAST Honeycomb Media (below) and fresh
air provide an ideal environment for a beneficial colony
of aerobic
(oxygen requiring) micro-organisms to thrive. This colony is referred
to as a fixed biomass. The fixed biomass
actively consumes all
biological waste.
[5] Clear
and odorless, neutralized water exits MicroFAST ready for standard or
innovative dispersal.
|
|
 |
|
The
MicroFAST Honeycomb Media provides the high surface to volume ratio to
maintain exceptional biomass growth during peak, average and low
usage. All organic contaminants like proteins, carbohydrates, lipids,
viruses and other toxic micro-organisms are completely consumed by the
fixed biomass. The biomass remains "fixed" and
"activated" within the aeration zone to consume all new
incoming waste, venting only simple carbon dioxide and air.
MicroFAST® are designed for use in all configurations of residential homes,
recreational dwellings and clustered housing developments. The larger
MicroFAST® Septic
Systems are also recommended for upgrading struggling municipal sewage
treatment plants, providing affordable options versus centralized sewer
systems. |
 |
|
 |
|
Nitrogen Reduction
Nitrification and denitrification projects become simple using MicroFAST®
treatment technology. The multiple biological, bio-chemical, chemical
and physical processes that occur simultaneously in MicroFAST® have
been proven to consistently reduce nitrogen levels, including nitrates
and all nitrogen species. |
|
 |
|
MicroFAST® Septic
System Options
Above-Ground Septic Systems
For property with dense clay, heavy rock, bog or swamp where in-ground
installation is not practical, we can provide any model of MicroFAST® in an
above-ground configuration. Above-ground MicroFAST® come in
concrete, fiberglass or steel tanks. Seen here is a MicroFAST 0.75 in a 2
chamber fiberglass tank with UV Light System.
Phosphate
Reduction Units
Certain jurisdictions require that phosphate output be reduced to 1 mg/
Liter. We can provide an attachment to your MicroFAST® for
this application. There are no chemicals to mix.
Clean out and removal is necessary only every 15 years.
Discharge Pump Chambers
If treated wastewater is required to be discharged to a dispersal site
under pressure, a pump chamber and pump are available.
Ultraviolet Light Systems
Ultraviolet systems include automatic self-monitoring systems to
notify you if the UV lamp needs cleaning or replacement. With UV, the
fecal coliform count can be reduced to less than 200 CFU/100ml. With a
pre-filter on the UV unit, the fecal coliform count can be reduced to
less than 2 CFU/100ml. Under local regulations, the neutralized water
may be re-used and recycled for many non-drinking applications such as
spray or drip irrigation, flushing toilets and urinals.
The FAST Honeycomb
Media, receiving water mixed with fresh air from the air-lift pump,
provides an ideal environment for a beneficial colony of aerobic (oxygen
requiring) micro-organisms to thrive and fix to the honeycomb. The
colony is referred to as a fixed biomass. Populating the
honeycomb, inside the FAST bio-reactor, the biomass consumes all
incoming organic matter.
The FAST®
wastewater cleansing process continues as the biomass is supplied with
food (new incoming waste) and oxygen from the air-lift pump. All organic
contaminants including proteins, carbohydrates and lipids are
completely metabolized, venting only air and carbon dioxide;
and releasing only clear, odorless water.
FAST® Septic Systems are warranted and virtually maintenance free. FAST®
Bio-reactor modules contain no sewage pumps, no screens, filters or
moving parts to remove, replace or clean. All internal parts are made
from durable, long-lasting plastic, not subject to deterioration.
Based on environmentally
sound, proven scientific principles, FAST® is state-of-the-art
technology. The F.A.S.T. (fixed activated sewage treatment) employs a
unique hybrid combination of attached and suspended growth in an aerobic
packed bed bio-reactor. The fixed-film activated sludge integration
combines the stability of a fully-submerged fixed-film media along
with the powerful activated sludge treatment, making FAST® Systems
technologically advanced, completely reliable an
extraordinarily economical. Also see
MicroFAST®
Residential Septic
Systems. |
|
Ampac can also provide a
Timer Based Point of Distribution system for irrigation as follows: |
|
 |
|